OBIS Codes as per IEC62056-61

The Object Identification System (OBIS) is Part 61 of IEC62056, which defines the identification codes for commonly used data items in electricity metering equipment. The below are the (partial) list of OBIS codes supported by Microstar smart meters*.

* For reference only. Subject to change without notice. For the full list of OBIS codes, please refer to the product manual or contact Microstar support. 

OBIS CodeDescription
1-0:0.9.2Current Date
1-0:0.9.1Current Time
1-0:0.0.0Meter NO.
1-1:1.8.0Total active import energy
1-1:2.8.0Total active export energy
1-1:3.8.0Total reactive Import energy
1-1:4.8.0Total reactive export energy
1-1:5.8.0Total reactive energy Q1
1-1:6.8.0Total reactive energy Q2
1-1:7.8.0Total reactive energy Q3
1-1:8.8.0Total reactive energy Q4
1-1:9.8.0Total apparent import energy
1-1:10.8.0Total apparent export energy
1-1:1.8.0*XTotal active import energy of previous month (0 < X <16)
1-1:2.8.0*XTotal active export energy of previous month (0 < X <16)
1-1:3.8.0*XTotal reactive import energy of previous month (0 < X <16)
1-1:4.8.0*XTotal reactive export energy of previous month (0 < X <16)
1-1:9.8.0*XTotal apparent import energy of previous month (0 < X <16)
1-1:10.8.0*XTotal apparent export energy of previous month (0 < X <16)
1-1:1.8.1Active import energy of current month in Tariff 1
1-1:1.8.2Active import energy of current month in Tariff 2
1-1:1.8.3Active import energy of current month in Tariff 3
1-1:1.8.4Active import energy of current month in Tariff 4
1-1:2.8.1Active export energy of current month in Tariff 1
1-1:2.8.2Active export energy of current month in Tariff 2
1-1:2.8.3Active export energy of current month in Tariff 3
1-1:2.8.4Active export energy of current month in Tariff 4
1-1:1.8.1*XActive import energy of previous month in Tariff 1 (0 < X <16)
1-1:1.8.2*XActive import energy of previous month in Tariff 2 (0 < X <16)
1-1:1.8.3*XActive import energy of previous month in Tariff 3 (0 < X <16)
1-1:1.8.4*XActive import energy of previous month in Tariff 4 (0 < X <16)
1-1:2.8.1*XActive export energy of previous month in Tariff 1 (0 < X <16)
1-1:2.8.2*XActive export energy of previous month in Tariff 2 (0 < X <16)
1-1:2.8.3*XActive export energy of previous month in Tariff 3 (0 < X <16)
1-1:2.8.4*XActive export energy of previous month in Tariff 4 (0 < X <16)
1-1:21.8.0Phase A active import energy
1-1:41.8.0Phase B active import energy
1-1:61.8.0Phase C active import energy
1-1:22.8.0Phase A active export energy
1-1:42.8.0Phase B active export energy
1-1:62.8.0Phase C active export energy
1-1:23.8.0Phase A reactive import energy
1-1:43.8.0Phase B reactive import energy
1-1:63.8.0Phase C reactive import energy
1-1:24.8.0Phase A reactive export energy
1-1:44.8.0Phase B reactive export energy
1-1:64.8.0Phase C reactive export energy
1-1:1.6.0Active Maximum demand (import)
1-1:2.6.0Active Maximum demand (export)
1-1:1.6.1Active Maximum demand (import) in Tariff 1
1-1:1.6.2Active Maximum demand (import) in Tariff 2
1-1:1.6.3Active Maximum demand (import) in Tariff 3
1-1:1.6.4Active Maximum demand (import) in Tariff 4
1-1:2.6.1Active Maximum demand (export) in Tariff 1
1-1:2.6.2Active Maximum demand (export) in Tariff 2
1-1:2.6.3Active Maximum demand (export) in Tariff 3
1-1:2.6.4Active Maximum demand (export) in Tariff 4
1-1:3.6.0Reactive Maximum demand (import)
1-1:4.6.0Reactive Maximum demand (export)
1-1:9.6.0Apparent Maximum demand (import)
1-1:10.6.0Apparent Maximum demand (export)
1-1:1.5.0Import active total power at apparent demand
1-1:1.5.1Import active tariff 1 power at apparent demand
1-1:1.5.2Import active tariff 2 power at apparent demand
1-1:1.5.3Import active tariff 3 power at apparent demand
1-1:1.5.4Import active tariff 4 power at apparent demand
1-1:2.5.0Export active total power at apparent demand
1-1:2.5.1Export active tariff 1 power at apparent demand
1-1:2.5.2Export active tariff 2 power at apparent demand
1-1:2.5.3Export active tariff 3 power at apparent demand
1-1:2.5.4Export active tariff 4 power at apparent demand
1-1:21.7.0Instantaneous active import power of phase A
1-1:22.7.0Instantaneous active export power of phase A
1-1:23.7.0Instantaneous reactive import power of phase A
1-1:24.7.0Instantaneous reactive export power of phase A
1-1:29.7.0Instantaneous apparent import power of phase A
1-1:30.7.0Instantaneous apparent export power of phase A
1-1:31.7.0Instantaneous current of phase A
1-1:32.7.0Instantaneous voltage of phase A
1-1:33.7.0Instantaneous power factor of phase A
1-1:41.7.0Instantaneous active import power of phase B
1-1:42.7.0Instantaneous active export power of phase B
1-1:43.7.0Instantaneous reactive import power of phase B
1-1:44.7.0Instantaneous reactive export power of phase B
1-1:49.7.0Instantaneous apparent import power of phase B
1-1:50.7.0Instantaneous apparent export power of phase B
1-1:51.7.0Instantaneous current of phase B
1-1:52.7.0Instantaneous voltage of phase B
1-1:53.7.0Instantaneous power factor of phase B
1-1:61.7.0Instantaneous active import power of phase C
1-1:62.7.0Instantaneous active export power of phase C
1-1:63.7.0Instantaneous reactive import power of phase C
1-1:64.7.0Instantaneous reactive export power of phase C
1-1:69.7.0Instantaneous apparent import power of phase C
1-1:70.7.0Instantaneous apparent export power of phase C
1-1:71.7.0Instantaneous current of phase C
1-1:72.7.0Instantaneous voltage of phase C
1-1:73.7.0Instantaneous power factor of phase C
1-1: 1.7.0Instantaneous active import power
1-1: 2.7.0Instantaneous active export power
1-1: 3.7.0Instantaneous reactive import power
1-1: 4.7.0Instantaneous reactive export power
1-1: 9.7.0Instantaneous apparent import power
1-1:10.7.0Instantaneous apparent export power
1-1:13.7.0Instantaneous power factor